• GreatAlbatross@feddit.ukM
      link
      fedilink
      English
      arrow-up
      0
      ·
      edit-2
      12 days ago

      I’ll write a quick gist for anyone coming along:

      One gas boiler in the house, each room has a smart TRV.
      PIR sensor to set room presence, each window has an opening mag sensor. HASS has a general presence sensor set.

      Each room’s temperature is targeted based on presence and window status:
      For each room, if person is home at all, and has been in the room for 5 mins, and the window is closed, TRV to 19, boiler on if <19.
      If the room presence is negative and the window is closed, drop TRV target to 16.
      If the window is open, drop the TRV target to 7.

      There is a little more detail that that in the article, but that’s the basics.